Application Tag Commands
128 Command Set
The response to the LoadImage command is an ACK with the written EPC data. The
format of the response is:
LoadImage embedded in a Read Tag Multiple takes the following form:
BlockReadLock
Sub Command=0x0009
This command allows four-word blocks of User Memory to be read locked. Once read
locked the correct Access Password will be required to read the contents of the locked
blocks with Read Tag Data (28h)
.
FF XX 2D 00 00 05 44 00 03 XX XX ... ?? ??
SOH Length OpCode Status Chip
Type
Option Sub
Cmd
EPC Data CRC
FF XX 22 04 00 04 03 E8
11 22 33 44 00 00 00 78 08 38
SOH Length OpCode Options
(EPC Mem)
Search
Flags
Timeout Access Password Select Data Address
(bits)
Select
Data
Length
(bits)
Select
Data
01 5F 2D
00 00
05 40
00 03
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
Embd Cmd
Timeout
(Not Used)
Chip
Type
Option Sub Cmd
11 11 22 22 00 00 00 00 11 22 33 44 XX XX (76 bytes) ?? ??
Current Access Pwd Kill Password New Access Password PC Word EPC + User
Data
CRC