Set Application Commands
Command Set 167
Note
Setting the parameters using Set Protocol Configuration will override the
implicit value set by a previous call to Set User Mode. Likewise, a
subsequent call to Set User Mode will override the parameters set by Set
Protocol Configuration. Get Protocol Configuration will always return the
current setting regardless of whether it was set by Set Protocol
Configuration or Set User Mode.
Note
Changing these protocol parameters manually using
Set Protocol Configuration
(9Bh) will maintain their value across changes in the current protocol using
Set Current Tag Protocol (93h). Their values will NOT be reset if the protocol is
reset, only if the module is power cycled or the application firmware is
reloaded by a Start Bootloader (09h) followed by a Boot Firmware (04h).
Examples
Session
The following example sets the Gen2 session to S2:
Q Value
The Q valued can be set to a static user specified value or to dynamically change based
on ThingMagic internal algorithms. When using the dynamic Q setting the Value
parameter is dropped in the command.
The following example statically sets the Q value to 6:
The following example sets dynamic Q value adjusting:
FF 03 9B 05 00 02 DC EA
SOH Length OpCode Protocol Parameter Value CRC
FF 04 9B 05 12 01 06 80 A9
SOH Length OpCode Protocol Parameter Option Value CRC
FF 03 9B 05 12 00 CE E8
SOH Length OpCode Protocol Parameter Option CRC