Application Tag Commands
134 Command Set
Note
Only the G2i command can be performed as an embedded operation in a
Read Tag Multiple. The G2x version cannot.
The response to the Reset ReadProtect command is a simple ACK with standard status:
Reset ReadProtect embedded in a Read Tag Multiple take the following form:
Change EAS
The NXP command Change EAS sets or resets the EAS system bit. When set, the tag
will return an alarm code if an “EAS Alarm” command is received. This command takes
an additional field:
FF 10 2D 03 E8 02 44 00 02 00 00 00 78 08 34 11 22 33 44 ?? ??
SOH Length OpCode Timeout (ms) Chip
Type
Option Sub
Cmd
Select Data Address Select
Length
Selct
Data
Access Password CRC
FF 04 2D 00 00 02 44 00 02 ?? ??
SOH Length OpCode Status Chip
Type
Option Sub
Cmd
CRC
FF 1C 22 04 00 04 03 E8
11 22 33 44 00 00 00 78 08 34
SOH Length OpCode Options
(EPC Mem)
Search
Flags
Timeout Access Password Select Data Address
(bits)
Select
Data
Length
(bits)
Select
Data
01 0A 2D
00 00
02 40
00 02
11 22 33 44
?? ??
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
Embd Cmd
Timeout
(Not Used)
Chip
Type
Option Sub Cmd Access Password) CRC
Seitenansicht 133